Kia Sorento: Shift Cable Adjustment
| Adjusting method for T/M control cable |
| 1. |
Set room side shift lever and T/M side manual control lever to
"N" position.
|
| 2. |
Connect room side shift lever and shift cable.
|
| 3. |
Push cable to "F" direction shown to eliminate FREE PLAY.
|
| 4. |
Tighten adjusting nut (A).
|
| 5. |
After adjusting according check to be sure that this part operates
surely at each range of T/M side corresponding to each position of shift
lever.
|
Shift Cable InstallationCircuit Diagram
...
Circuit Diagram
...
ECM Problem Inspection Procedure
1.
TEST ECM GROUND CIRCUIT: Measure resistance between ECM and chassis
ground using the backside of ECM harness connector as ECM side check
point. If the problem is fo ...