[Rotor] |
1. |
Check that there is continuity between the slip rings (C).
|
2. |
Check that there is no continuity between the slip rings and the
rotor (B) or rotor shaft (A).
|
3. |
If the rotor fails either continuity check, replace the alternator.
|
[Stator] |
1. |
Check that there is continuity between each pair of leads (A).
|
2. |
Check that there is no continuity between each lead and the coil
core.
|
3. |
If the coil fails either continuity check, replace the alternator.
|
Cooling Fan Specification
[Cooling fan control module]
Items
Specification
Input
Signal Frequency ( Hz)
300 ± 5%
Duty (%)
OFF
10
Normal
...
Starter Installation
1.
Install in the reverse order of removal.
Starter installation bolt:
49.0 ~ 63.7 N.m (5.0 ~ 6.5 kgf.m, 36.2 ~ 47.0 lb-ft)
...
Before driving
Before entering vehicle
Be sure that all windows, outside mirror(s), and outside lights are clean.
Check the condition of the tires.
Check under the vehicle for any sign of leaks.
Be sure th ...