Kia Sorento: Cooling Fan Specification
| Items |
Specification |
||
| Input |
Signal Frequency ( Hz) |
300 ± 5% |
|
| Duty (%) |
OFF |
10 |
|
| Normal |
30 ~ 90 |
||
| Max. |
90 |
||
| Voltage level (V) |
HI |
Above. 0.7 |
|
| LOW |
0 ~ 1.9 |
||
| Max, Load current consumption (A) |
21.0 + 10% [Ref = 12V] |
||
| Items |
Specification [Ref = 12V] |
| Fan speed control type |
PWM |
| Fan speed (rpm) |
1,970 ±10% |
| Current (A) |
20.8 ± 10% |
Cooling Fan DescriptionWave Form
...
ESC Control Module Removal
1.
Turn the ignition switch OFF.
2.
Remove the surge tank. [G3.3 GDI]
(Refer to Engine Mechanical System - "Surge Tank")
...
Installation
•
Note that internal damage may occur when the component
is dropped. If the component ...