Item |
Specification |
||
Compressor |
Type |
DVE18 (External Variable Displacement Swash Plate) |
|
Oil type & Capacity |
Front only |
PAG 120± 10cc (4.1±0.3oz.) |
|
Front & Rear |
PAG 180 ± 10cc (6.1±0.3oz.) |
||
Pulley type |
6PK-TYPE |
||
Displacement |
180cc/rev |
||
Condenser |
Heat rejection |
DSL : 14,600-5% kcal/hr (16.1-5% kw) GSL : 16,000-5% kcal/hr (18.8-5% kw) |
|
Expansion valve |
Type |
Block type |
|
Refrigerant |
Type |
HFC-134a |
|
Capacity |
Front only |
600 ± 25g (21.1 ± 0.88oz.) |
|
Front & Rear |
750 ± 25g (26.4 ± 0.88oz.) |
Item |
Specification |
|
Fresh and recirculation |
Operating method |
Actuator |
Blower |
Type |
Sirocco |
Speed step |
Auto + 8 speed (Automatic), 1~4speed (Manual) |
|
Speed control |
Power mosfet (Automatic), Resistor (Manual) |
|
Air filter |
Type |
Particle filter |
Item |
Specification |
|
Heater |
Type |
Pin & Tube type |
Heating capacity |
4,700 - 5% kcal/hr |
|
Mode operating method |
Actuator |
|
Temperature operating method |
Actuator |
|
Evaporator |
Temperature control type |
Evaporator temperature sensor |
A/C ON/OFF |
ON: 3.0±0.3°C (37.4±0.5°F) OFF: 1.0±0.3°C (33.8±0.5°F) |
Oil hydraulic Motor(Actuator) Installation
1.
Before installation, wipe the surface with a clean cloth.
2.
Check the O-rings (A) of the new hydraulic motor (actuators).
...
Cooling Fan Control Module Circuit Diagram
...
Cylinder Head Cover Removal
1.
Disconnect the battery negative terminal.
2.
Remove the engine cover.
3.
Remove the air duct and air cleaner ...