1. |
There should be continuity between the No.1 and No.3 terminals
when power and ground are connected to the No.2 and No.10 in the ICM-A.
|
1. |
There should be continuity between the No.16 and No.15 terminals
when power and ground are connected to the No.13 and No.14 in the ICM-A.
|
1. |
There should be continuity between the No.8 and No.20 terminals
when power and ground are connected to the No.13 and No.12 in the ICM-A.
|
1. |
There should be continuity between the No.19 and No.7 terminals
when power and ground are connected to the No.13 and No.11 in the ICM-B.
|
1. |
There should be continuity between the No.12 and No.22 terminals
when power and ground are connected to the No.21 and No.22 in the ICM-B.
|
1. |
There should be continuity between the No.17 and No.4 terminals
int the ICM-A when power and ground are connected to the No.2 and No.1
in the ICM-B.
|
1. |
There should be continuity between the No.20 and No.16 terminals
when power and ground are connected to the No.17 and No.6 in the ICM-B.
|
1. |
There should be continuity between the No.15 and No.13 terminals
when power and ground are connected to the No.5 and No.9 in the ICM-B.
|
1. |
There should be continuity between the No.6 and No.18 terminals
in the ICM-A when power and ground are connected to the No.4 and No.3
in the ICM-B.
|
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components, first determine
if the malfunction is due to the refrigerant charge, air flow or compressor.
Us ...
Antenna Installation
1.
Connect the roof antenna cables and connectors.
2.
Install the rear roof trim.
...
Signal Waveform
...