Items |
Specification |
||
Input |
Signal Frequency ( Hz) |
300 ± 5% |
|
Duty (%) |
OFF |
10 |
|
Normal |
30 ~ 90 |
||
Max. |
90 |
||
Voltage level (V) |
HI |
Above. 0.7 |
|
LOW |
0 ~ 1.9 |
||
Max, Load current consumption (A) |
21.0 + 10% [Ref = 12V] |
Items |
Specification [Ref = 12V] |
Fan speed control type |
PWM |
Fan speed (rpm) |
1,970 ±10% |
Current (A) |
20.8 ± 10% |
Spark Plug Specification
Item
Specification
Type
FXU16HR11
Gap
1.0 ~1.1 mm
(0.0394 ~ 0.0433 in.)
...
Evaporator Temperature Sensor Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater and blower assembly.
(Refer to Heater - "Heater Unit")
...
Specifications
Direct control VFS[UD/B]
▷ Control type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
539.370 ~ 0 ( 5.5 ~ 0, 78.23 ~ 0)
Current value(mA)
...