1. |
Check IPM input/output specification of multifunction switch using
the GDS. If the specification is abnormal, replace the lamp or wiper
switch.
|
2. |
If diagnosis is required on the multifunction switch, select model
and "IPM".
|
3. |
Select "Current data" and check the input/output condition of
"Multifunction switch".
|
4. |
To perform test on "Multifunction switch" outputs, select "Actuation
test".
|
Brake Pedal Adjustment
Brake Pedal Height and Free Play
1.
Disconnect the stop lamp switch connector (A) and loosen the stop
lamp switch lock nut.
2. ...
Compressor Components
1. Center Bolt
2. Hub Bolt
3. Hub Assembly
4. Snap Ring
5. Pulley
6. Compressor Assembly
7. Electric Control Valve
...
Shift Cable Installation
1.
Install in the reverse order of removal.
Set shift lever and inhibitor ...