Direct control VFS[T/CON]
▷ Control type : Normal low type
Control Pressure kpa
(kgf/cm², psi)
0 ~ 539.37 (0 ~ 5.5, 0 ~ 78.23)
Current value(mA)
0 ~ 850
Internal resistance(Ω)
5.1 ± 0.3

Torque Converter Control Solenoid Valve (T/CON_VFS)
Torque converter control solenoid valve (T/CON) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque converter. ...

Circuit Diagram
...

See also:

Cooling Fan Specification
[Cooling fan control module] Items Specification Input Signal Frequency ( Hz) 300 ± 5% Duty (%) OFF 10 Normal ...

Removal
1. Disconnect the battery negative cable from the battery and then wait for at least 30 seconds. 2. Turn the steering wheel so that the fr ...

Shift Lever Installation
1. Install in the reverse order of removal.    Set shift lever and inhibitor ...