Adjusting method for T/M control cable |
1. |
Set room side shift lever and T/M side manual control lever to
"N" position.
|
2. |
Connect room side shift lever and shift cable.
|
3. |
Push cable to "F" direction shown to eliminate FREE PLAY.
|
4. |
Tighten adjusting nut (A).
|
5. |
After adjusting according check to be sure that this part operates
surely at each range of T/M side corresponding to each position of shift
lever.
|
Tightening Torques
Item
kgf.m
N.m
lb-ft
Positive Crankcase Ventilation (PCV) Valve installation
0.19 ~ 0.29
1.9 ~ 2.8
1.4 ~ 2.1
...
Operation and Leakage Check
Check all of the following items:
Component
Procedure
Brake Booster (A)
Check brake operation by applying the brakes during a test drive.
If the brakes do not ...
Rear Coil Spring Inspection
1.
Check the spring for distortion, aging or damage.
2.
Check the spring upper pad and lower pad for aging or damage.
...