Kia Sorento: Installation
•
|
Install the component with the specified torques.
|
•
|
Note that internal damage may occur when the component
is dropped. If the component has been dropped, inspect before
installing.
|
|
•
|
Apply engine oil to the valve O-ring.
|
|
1. |
Install in the reverse order of removal.
CVVT oil control valve installation
bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
|
|
1.
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
2.
Disconnect the CVVT oil control valve connector (A).
...
Variable Intake manifold Solenoid (VIS) valve is installed on the intake
manifold. The VIS valve controls the vacuum modulator which activates a valve
in the intake manifold. The ECM opens or ...
See also:
Alternator Circuit Diagram
•
COM signal - When
controlling the voltage generated, the ECM sends the target
...
Inspection
1.
Check the signal waveform of the CMPS and CKPS using the GDS.
Specification:
Refer to “Wave Form”
...
Instrument Cluster Installation
1.
Connect the cluster connector.
2.
Install the cluster assembly.
3.
Install the cluster facia panel.
...